Skip to Content

7310

(0 review)

Discharge equipment with pressure gauge and filter in the shut-off valve for backpack sprayer type 3552.., 3558…, FPM seals

$ 74.65 $ 74.65
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Spray line with pressure gauge and filter in the shut-off valve for backpack sprayer type 3552.., 3558…, FPM seals.

 
EAN4000903731007
Article typeSpare part and accessory
Max. operating pressure6 bar/88 psi/0.6 MPa
Shut-off valve materialPlastic
Shut-off valve connectionD10
Hose diameterD10
Scope of delivery generalHose, shut-off valve
Device equipmentSafety interlock on the shut-off valve prevents unintentional spraying., ede51def-2f4b-48fa-b6c2-bb3852e24d11

Devices may not be used for spraying plant protection liquids.

Only trained, healthy and rested people may work with the device. You should not be under the influence of alcohol, drugs or medication.

Children and adolescents must not use the device. Keep the spraying devices safe from access to children.

Take precautions to prevent hazardous substances from being misused.

→ Accident risk!

Keep bystanders away during spraying.

Never spray on people, animals, electrical devices and lines, into the wind, or into bodies of water.

→ Risk of injury!

Wear appropriate protective clothing, goggles and respiratory protection in line with the applicable national regulations when working with hazardous substances.

Avoid ignition sources in the environment.

Do not allow the device to remain under pressure and/or exposed directly to sunlight. Make certain the device is not heated beyond the maximum operating temperature. (→Table 1).

Protect the device from frost and ammonia.

Never blow through the nozzles or valves with your mouth.

→ Risk of poisoning!

There is a risk of slipping or tripping on smooth or wet surfaces, snow, ice, on slopes and on uneven terrain.

Repairs and modifications to the device are not permitted. Have damaged parts or parts that do not work properly repaired immediately by our customer service department or by service partners authorized by us.

The effect of the safety valve must not be bypassed or made inoperative.

→ Explosion hazard!

Use only original spare and accessory parts. We cannot assume any liability resulting from the use of third-party parts.

When pumping, always observe the pressure gauge to ensure the maximum

spraying pressure is not exceeded (→ Table 1).

All excess pressure must be released from the device before filling, after use, before carrying out maintenance work, on work breaks, and before placing it in storage.

Points to note when transporting the device: Transport the device in such a way that it is protected against damage and tipping. All excess pressure must be released from the device.

→ Explosion hazard!

If the device leaks at the container, immediately depressurise the device and put it out of operation!

→ Risk of explosion!